This product area covers detecors for combustible gases, H2S and toxic gases, as well as intelligent controller and sampler for a complete system solution.
S4100C
Intelligent Sensor for Combustible Gases
– Compact Hydrocarbon Transmitter
– EExem Design
– SIL3 suitable, IEC61508
– Display up to 120% LEL
– Output: 4-20 mA and Open Collector
– High-quality catalytic sensor element
– High longterm stability
– High poison resistance
– Temperature range sensor: up to +180°C
– Approvals: ATEX, GOST R&K
– Typical lifetime of 6-8 years
S4000CH
Intelligent Sensor for Combustible Gases
– Compact Hydrocarbon Transmitter
– EExd Design
– SIL3 suitable, IEC61508
– Display up to 120% LEL
– Output: 4-20 mA, Relays and HART optional
– High-quality sensor element
– Remaining sensor life indication
– High longterm stability
– High poison resistance
– Approvals: ATEX, CSA/FM, GOST
– Typical lifetime of 6 to 8 years
IR4000S
Infrared Single-Point Hydrocarbon Gas Detector
– Intelligent IR Hydrocarbon Transmitter
– Explosion-proof enclosure
– LED display with magnetic interface
– SIL2 suitable, IEC61508
– Display up to 120% LEL
– Output: 4-20 mA, Relays and HART optional
– Heated Infrared Optic
– Poison resistant
– Approvals: ATEX, IECEx, FM, CSA
– Typical lifetime: 10 to 15 years
CGS500
Thermocatalytic Gassensor
– For combustible gases and solvents
– Temperature compensated
– Poison resistant
– Long lifetime
– Corrosion resistant stainless steel sensor
– ATEX II 2 G EEx d IIC T6
S500-IR
Infrared (IR) Point Gas Detector
with LED Display and Relays
– SIL2 suitable, EN 61508, EN 50402
– Standalone operation
– 4-20 mA analogue signal
– Voltage free Relay contac
– One person calibrationn
– Reference- and dection wavelength
– Temperature compensation
– Sef-monitoring and fail safe
– Corrosion resistant stainless steel sensor
– ATEX EExd IIC T6
– Low maintenance NDIR-technology
– Typical lifetime: 10-15 years
(Kopie 7)
[Translate to Englisch:]
CGS500-IR
Infrarot Gassensor
– Wartungsarme NDIR Technologie
– Temperaturkompensiert
– Geringe Drift
– Goldbedampfte Messzelle gegen korrosive Gase
– Beheizte Messzelle
– Korrosionsbeständiger Edelstahlsensor
– ATEX II 2 G EEx d IIC T6
– Standzeit typisch 10 Jahre
(Kopie 8)
[Translate to Englisch:]
Katalytischer Sensor
vergiftungsresistent
– ATEX-geprüfter Sensor
– Ausgelegt für alle Kohlenwasserstoffe und Lösemittel
– Typ 11159-1 CENELEC/GOST-geprüft -54 bis +120°C max
– Typ 11159-2 CENELEC/GOST-geprüft -54 bis +180°C max
PDF-Download
(Kopie 9)
[Translate to Englisch:]
Tragbare Kalibrierausrüstung
für Gaswarnsysteme und brennbarer Gase
– Folgende Kalibriergase sind u.a. erhältlich: Butadien, Butan, Äthan Wasserstoff, Methan, Propan und diverse Lösemittel
PDF-Download
(Kopie 10)
[Translate to Englisch:]
IR5000
Open-Path System für brennbare Gase
– 0-5000 ppm x m und 0-5 UEG x m mit 2 getrennten 4-20mA Ausgängen
– Digitale Vorort-Anzeige für Konzentration, Fehlercodes und Transmission
– RS 485 Schnittstelle
– Mikroprozessorsteuerung
– Selbstüberwachung mit neun verschiedenen Diagnosemeldungen
– Pfadlänge bis zu 100 m
– Sehr geringer Wartungsaufwand
– Selektiv